Fairbanks Ward Generator Manual
Dec 22, 2011. Gillette-Fairbanks Ward USA 4000 watts AC (not surge power) model RH-40, Serial # EH-20-16. 4 cycle 8 hp @3600 rpm air cooled Briggs and Stratton, recoil start, manual choke, 4 quart fuel tank and has the chrome plated piston and aluminum alloy cylinder that better dissipates heat. Two pole self.
A diesel locomotive is a type of railwaylocomotive in which the prime mover is a diesel engine. Several types of diesel locomotive have been developed, differing mainly in the means by which mechanical power is conveyed to the driving wheels.
Early internal combusition locomotives and railcars used kerosene and gasoline as their fuel. Dr. Rudolf Diesel patented his first compression ignition engine[1] in 1898, and steady improvements in the design of diesel engines reduced their physical size and improved their power-to-weight ratio to a point where one could be mounted in a locomotive. Internal combustion engines only operate efficiently within a limited torque range, and while low power gasoline engines can be coupled to a mechanical transmission, the more powerful diesel engines required the development of new forms of transmission.[2][3][4][5][6]
The first successful diesel engines used diesel–electric transmissions, and by 1925 a small number of diesel locomotives of 600 hp (450 kW) were in service in the United States. In 1930, Armstrong Whitworth of the United Kingdom delivered two 1,200 hp (890 kW) locomotives using Sulzer-designed engines to Buenos Aires Great Southern Railway of Argentina. In 1933, diesel-electric technology developed by Maybach was used propel the DRG Class SVT 877, a high-speed intercity two-car set, and went into series production with other streamlined car sets in Germany starting in 1935. In the USA, diesel-electric propulsion was brought to high-speed mainline passenger service in late 1934, largely through the research and development efforts of General Motors from 1930–34 and advances in lightweight carbody design by the Budd Company.
The economic recovery from the Second World War saw the widespread adoption of diesel locomotives in many countries. They offered greater flexibility and performance than steam locomotives, as well as substantially lower operating and maintenance costs. Diesel–hydraulic transmissions were introduced in the 1950s, but from the 1970s onwards diesel–electric transmission has dominated.[citation needed]
- 1History
- 1.2Early diesel locomotives and railcars in US
- 1.3Early diesel locomotives and railcars in Europe
- 1.4Early diesel locomotives and railcars in Asia
- 2Transmission types
- 2.2Diesel–electric
- 2.3Diesel–hydraulic
- 2.3.2Hydrokinetic transmission
- 2.3.2.2Multiple units
- 2.3.2Hydrokinetic transmission
- 3Multiple-unit operation
- 4Fittings and appliances
- 5Environmental impact
- 8References
History[edit]
Adaptation of the diesel engine for rail use[edit]
The earliest recorded example of the use of an internal combustion engine in a railway locomotive is the prototype designed by William Dent Priestman, which was examined by William Thomson, 1st Baron Kelvin in 1888 who described it as a '[Priestman oil engine] mounted upon a truck which is worked on a temporary line of rails to show the adaptation of a petroleum engine for locomotive purposes.'[7][8] In 1894, a 20 hp (15 kW) two axle machine built by Priestman Brothers was used on the Hull Docks.[9][10] In 1896 an oil-engined railway locomotive was built for the Royal Arsenal, Woolwich, England, in 1896, using an engine designed by Herbert Akroyd Stuart.[11] It was not, strictly, a diesel because it used a hot bulb engine (also known as a semi-diesel) but it was the precursor of the diesel.
Following the expiration of Dr. Rudolf Diesel's patent in 1912, his engine design was successfully applied to marine propulsion and stationary applications. However, the massiveness and poor power-to-weight ratio of these early engines made them unsuitable for propelling land-based vehicles. Therefore, the engine's potential as a railroad prime mover was not initially recognized.[12] This changed as development reduced the size and weight of the engine.
In 1906, Rudolf Diesel, Adolf Klose and the steam and diesel engine manufacturer Gebrüder Sulzer founded Diesel-Sulzer-Klose GmbH to manufacture diesel-powered locomotives. Sulzer had been manufacturing Diesel engines since 1898. The Prussian State Railways ordered a diesel locomotive from the company in 1909, and after test runs between Winterthur and Romanshorn the diesel–mechanical locomotive was delivered in Berlin in September 1912. The world's first diesel-powered locomotive was operated in the summer of 1912 on the Winterthur–Romanshorn railroad in Switzerland, but was not a commercial success.[13] During further test runs in 1913 several problems were found. After the First World War broke out in 1914, all further trials were stopped. The locomotive weight was 95 tonnes and the power was 883 kW with a maximum speed of 100 km/h (62 mph).[14] Small numbers of prototype diesel locomotives were produced in a number of countries through the mid-1920s.
Early diesel locomotives and railcars in US[edit]
Early American developments[edit]
Adolphus Busch purchased the American manufacturing rights for the diesel engine in 1898 but never applied this new form of power to transportation. He founded the Busch-Sulzer company in 1911.Only limited success was achieved in the early twentieth century with internal combustion engined railcars, due, in part, to difficulties with mechanical drive systems.[15]
General Electric (GE) entered the railcar market in the early twentieth century, as Thomas Edison possessed a patent on the electric locomotive, his design actually being a type of electrically-propelled railcar.[16] GE built its first electric locomotive prototype in 1895. However, high electrification costs caused GE to turn its attention to internal combustion power to provide electricity for electric railcars. Problems related to co-coordinating the prime mover and electric motor were immediately encountered, primarily due to limitations of the Ward Leonard current control system that had been chosen.[citation needed]GE Rail was formed in 1907 and 112 years later, in 2019, was purchased by and merged with Wabtec.
A significant breakthrough occurred in 1914, when Hermann Lemp, a GE electrical engineer, developed and patented a reliable direct current electrical control system (subsequent improvements were also patented by Lemp).[17] Lemp's design used a single lever to control both engine and generator in a coordinated fashion, and was the prototype for all internal combustion–electric drive control systems.
In 1917–18, GE produced three experimental diesel–electric locomotives using Lemp's control design, the first known to be built in the United States.[18] Following this development, the 1923 Kaufman Act banned steam locomotives from New York City because of severe pollution problems. The response to this law was to electrify high-traffic rail lines. However, electrification was uneconomical to apply to lower-traffic areas.
The first regular use of diesel–electric locomotives was in switching (shunter) applications, which were more forgiving than mainline applications of the limitations of contemporary diesel technology and where the idling economy of diesel relative to steam would be most beneficial. GE entered a collaboration with the American Locomotive Company (ALCO) and Ingersoll-Rand (the 'AGEIR' consortium) in 1924 to produce a prototype 300 hp (220 kW) 'boxcab' locomotive delivered in July 1925. This locomotive demonstrated that the diesel–electric power unit could provide many of the benefits of an electric locomotive without the railroad having to bear the sizeable expense of electrification.[19] The unit successfully demonstrated, in switching and local freight and passenger service, on ten railroads and three industrial lines.[20] Westinghouse Electric and Baldwin collaborated to build switching locomotives starting in 1929. However, the Great Depression curtailed demand for Westinghouse's electrical equipment, and they stopped building locomotives internally, opting to supply electrical parts instead.[21]
In June 1925, Baldwin Locomotive Works outshopped a prototype diesel–electric locomotive for 'special uses' (such as for runs where water for steam locomotives was scarce) using electrical equipment from Westinghouse Electric Company.[22] Its twin-engine design was not successful, and the unit was scrapped after a short testing and demonstration period.[23] Industry sources were beginning to suggest “the outstanding advantages of this new form of motive power”.[24] In 1929, the Canadian National Railways became the first North American railway to use diesels in mainline service with two units, 9000 and 9001, from Westinghouse.[25] However, these early diesels proved expensive and unreliable, with their high cost of acquisition relative to steam unable to be realized in operating cost savings as they were frequently out of service. It would be another five years before diesel-electric propulsion would be successfully used in mainline service, and nearly ten years before it would show real potential to fully replace steam.
Before diesel power could make inroads into mainline service, the limitations of diesel engines circa 1930 - low power-to-weight ratios and narrow output range - had to be overcome. A major effort to overcome those limitations was launched by General Motors after they moved into the diesel field with their acquisition of the Winton Engine Company, a major manufacturer of diesel engines for marine and stationary applications, in 1930. Supported by the General Motors Research Division, GM's Winton Engine Corporation sought to develop diesel engines suitable for high-speed mobile use. The first milestone in that effort was delivery in early 1934 of the Winton 201A, a two-stroke, Roots-blown, uniflow-scavenged, unit-injecteddiesel engine that could deliver the required performance for a fast, lightweight passenger train. The second milestone, and the one that got American railroads moving towards diesel, was the 1938 delivery of GM's Model 567 engine that was designed specifically for locomotive use, bringing a fivefold increase in life of some mechanical parts and showing its potential for meeting the rigors of freight service.[26]
Diesel–electric railroad locomotion entered mainline service when the Burlington Railroad and Union Pacific used custom-built diesel 'streamliners' to haul passengers, starting in late 1934.[15][27] Burlington's Zephyr trainsets evolved from articulated three-car sets with 600 hp power cars in 1934 and early 1935, to the Denver Zephyr semi-articulated ten car trainsets pulled by cab-booster power sets introduced in late 1936. Union Pacific started diesel streamliner service between Chicago and Portland Oregon in June 1935, and in the following year would add Los Angeles and Oakland California, and Denver Colorado to the destinations of diesel streamliners out of Chicago. The Burlington and Union Pacific streamliners were built by the Budd Company and the Pullman-Standard Company, respectively, using the new Winton engines and power train systems designed by GM's Electro-Motive Corporation. EMC's experimental 1800 hp B-B locomotives of 1935 demonstrated the multiple-unit control systems used for the cab/booster sets and the twin-engine format used with the later Zephyr power units. Both of those features would be used in EMC's later production model locomotives. The lightweight diesel streamliners of the mid-1930s demonstrated the advantages of diesel for passenger service with breakthrough schedule times, but diesel locomotive power would not fully come of age until regular series production of mainline diesel locomotives commenced and it was shown suitable for full-size passenger and freight service.
First American series production locomotives[edit]
Following their 1925 prototype, the AGEIR consortium produced 25 more units of 300 hp (220 kW) '60 ton' AGEIR boxcabswitching locomotives between 1925 and 1928 for several New York City railroads, making them the first series-produced diesel locomotives.[28] The consortium also produced seven twin-engine '100 ton' boxcabs and one hybrid trolley/battery unit with a diesel-driven charging circuit. ALCO acquired the McIntosh & Seymour Engine Company in 1929 and entered series production of 300 hp (220 kW) and 600 hp (450 kW) single-cab switcher units in 1931. ALCO would be the pre-eminent builder of switch engines through the mid-1930s and would adapt the basic switcher design to produce versatile and highly successful, albeit relatively low powered, road locomotives.
GM, seeing the success of the custom streamliners, sought to expand the market for diesel power by producing standardized locomotives under their Electro-Motive Corporation. In 1936, EMC's new factory started production of switch engines. In 1937, the factory started producing their new E series streamlined passenger locomotives, which would be upgraded with more reliable purpose-built engines in 1938. Seeing the performance and reliability of the new 567 model engine in passenger locomotives, EMC was eager to demonstrate diesel's viability in freight service.
Following the successful 1939 tour of EMC'sFT demonstrator freight locomotive set, the stage was set for dieselization of American railroads. In 1941, ALCO-GE introduced the RS-1 road-switcher that occupied its own market niche while EMD's F series locomotives were sought for mainline freight service. The US entry into World War II slowed conversion to diesel; the War Production Board put a halt to building new passenger equipment and gave naval uses priority for diesel engine production. During the petroleum crisis of 1942-43, coal-fired steam had the advantage of not using fuel that was in critically short supply. EMD was later allowed to increase the production of its FT locomotives and ALCO-GE was allowed to produce a limited number of DL-109 road locomotives, but most in the locomotive business were restricted to making switch engines and steam locomotives.
In the early postwar era, EMD dominated the market for mainline locomotives with their E and F series locomotives. ALCO-GE in the late 1940s produced switchers and road-switchers that were successful in the short-haul market. However, EMD launched their GP series road-switcher locomotives in 1949, which displaced all other locomotives in the freight market including their own F series locomotives. GE subsequently dissolved its partnership with ALCO and would emerge as EMD's main competitor in the early 1960s, eventually taking the top position in the locomotive market from EMD.
Early diesel–electric locomotives in the United States used direct current (DC) traction motors, but alternating current (AC) motors came into widespread use in the 1990s, starting with the Electro-Motive SD70MAC in 1993 and followed by the General Electric's AC4400CW in 1994 and AC6000CW in 1995.[29]
Early diesel locomotives and railcars in Europe[edit]
First functional diesel vehicles[edit]
In 1914, world's first functional diesel–electric railcars were produced for the Königlich-Sächsische Staatseisenbahnen (Royal Saxon State Railways) by Waggonfabrik Rastatt with electric equipment from Brown, Boveri & Cie and diesel engines from SwissSulzer AG. They were classified as DET 1 and DET 2 (de.wiki [de]). Due to shortage of petrol products during World War I, they remained unused for regular service in Germany. In 1922, they were sold to Swiss Compagnie du Chemin de fer Régional du Val-de-Travers (fr.wiki [fr]), where they were used in regular service up to the electrification of the line in 1944. Afterwards, the company kept them in service as boosters till 1965.
Fiat claims a first Italian diesel–electric locomotive built in 1922, but little detail is available. A Fiat-TIBB diesel–locomotive 'A', of 440CV, is reported to have entered service on the Ferrovie Calabro Lucane in southern Italy in 1926, following trials in 1924-5.[30]
In 1924, two diesel–electric locomotives were taken in service by the Soviet railways, almost at one time:
- The engine Ээл2 (Eel2 original number Юэ 001/Yu-e 001) started on October 22. It had been designed by a team led by Yuri Lomonosov and built 1923–1924 by Maschinenfabrik Esslingen in Germany. It had 5 driving axles (1'E1'). After several test rides, it hauled trains for almost three decades from 1925 to 1954.[31] Though proved to be world's first functional diesel locomotive, it did not become a series, but it became a model for several classes of Soviet diesel locomotives.
- The engine Щэл1 (Shch-el 1, original number Юэ2/Yu-e 2), started on November 9. It had been developed by Yakov Modestovich Gakkel (ru.wiki [ru]) and built by Baltic Shipyard in Saint Petersburg. It had ten driving axles in three bogies (1' Co' Do' Co' 1'). From 1925 to 1927, it hauled trains between Moscow and Kursk and in Caucasus region. Due to technical problems, afterwards, it was out of service. Since 1934, it was used as a stationary electric generator.
In 1935, Krauss-Maffei, MAN and Voith built the first diesel–hydraulic locomotive, called V 140, in Germany. The German railways (DRG) being very pleased with the performance of that engine, diesel–hydraulics became the mainstream in diesel locomotives in Germany. Serial production of diesel locomotives in Germany began after World War II.
Switchers[edit]
In many railway stations and industrial compounds, steam shunters had to be kept hot during lots of breaks between scattered short tasks. Therefore, diesel traction became economical for shunting before it became economical for hauling trains. The construction of diesel shunters began in 1920 in France, in 1925 in Denmark, in 1926 in the Netherlands, and in 1927 in Germany. After a few years of testing, hundreds of units were produced within a decade.
Diesel railcars for regional traffic[edit]
Diesel-powered or 'oil-engined' railcars, generally diesel–mechanical, were developed by various European manufacturers in the 1930s, e.g. by William Beardmore and Company for the Canadian National Railways (the Beardmore Tornado engine was subsequently used in the R101 airship). Some of those series for regional traffic were begun with gasoline motors and then continued with diesel motors, such as Hungarian BCmot (The class code doesn't tell anything but 'railmotor with 2nd and 3rd class seats'.), 128 cars built 1926 – 1937, or German Wismar railbuses (57 cars 1932 – 1941). In France, the first diesel railcar was Renault VH, 115 units produced 1933/34.In Italy, after 6 Gasoline cars since 1931, Fiat and Breda built a lot of diesel railmotors, more than 110 from 1933 to 1938 and 390 from 1940 to 1953, Class 772 known as Littorina, and Class ALn 900.
High-speed railcars[edit]
In the 1930s, streamlined highspeed diesel railcars were developed in several countries:
- In Germany, the Flying Hamburger was built in 1932. After a test ride in December 1932, this two coach diesel railcar (in English terminology a DMU2) started service at Deutsche Reichsbahn (DRG) in February 1933. It became the prototype of DRG Class SVT 137 with 33 more highspeed DMUs, built for DRG till 1938, 13 DMU 2 ('Hamburg' series), 18 DMU 3 ('Leipzig' and 'Köln' series), and 2 DMU 4 ('Berlin' series).
- French SNCF classes XF 1000 and XF 1100 comprised 11 high-speed DMUs, also called TAR, built 1934–1939.
- In Hungary, Ganz Works built Arpád railmotor (see hu.wiki [hu] and de.wiki [de]), a kind of a luxurious railbus in a series of 7 items since 1934, and started to build Hargita DMU amazingly in 1944 (see hu.wiki [hu])
Further developments[edit]
In 1945, a batch of 30 Baldwin diesel–electric locomotives, Baldwin 0-6-6-0 1000, was delivered from the United States to the railways of the Soviet Union.
In 1947, the London Midland & Scottish Railway introduced the first of a pair of 1,600 hp (1,200 kW) Co-Co diesel–electric locomotives (later British Rail Class D16/1) for regular use in the United Kingdom, although British manufacturers such as Armstrong Whitworth had been exporting diesel locomotives since 1930. Fleet deliveries to British Railways, of other designs such as Class 20 and Class 31, began in 1957.
Series production of diesel locomotives in Italy began in the mid-1950s. Generally, diesel traction in Italy was of less importance than in other countries, as it was amongst the most advanced countries in the electrification of the main lines and, as a result of Italian geography, even on many domestic connections freight transport over sea is cheaper than rail transport.
Early diesel locomotives and railcars in Asia[edit]
Japan[edit]
In Japan, starting in the 1920s, some petrol-electric railcars were produced. The first diesel–electric traction and the first air-streamed vehicles on Japanese rails were the two DMU3s of class Kiha 43000 (キハ43000系).[32] Japan's first series of diesel locomotives was class DD50 (国鉄DD50形), twin locomotives, developed since 1950 and in service since 1953.[33]
China[edit]
One of the first homes developed diesel vehicles of China was the DMU Dongfeng (东风), produced in 1958 by CSR Sifang.Series production of China's first diesel locomotive class, the DFH 1, began in 1964 following the construction of a prototype in 1959.
Early diesel locomotives and railcars in Australia[edit]
The Trans-Australian Railway built 1912 to 1917 by Commonwealth Railways (CR) passes through 2000 km of waterless (or salt watered) desert terrain unsuitable for steam locomotives. The original engineer Henry Deane envisaged diesel operation to overcome such problems.[34] Some have suggested that the CR worked with the South Australian Railways to trial diesel traction.[35] However, the technology was not developed enough to be reliable.
As in Europe, the usage of internal combustion engines advanced more readily in self-propelled railcars than in locomotives.
- Some Australian railway companies bought McKeen railcars.
- In the 1920s and 1930s, more reliable Gasoline railmotors were built by Australian industries.
- Australia's first diesel railcars were the NSWGR 100 Class (PH later DP) Silver City Comet cars in 1937.[36]
- High-speed vehicles for those days' possibilities on 3 ft 6 in (1,067 mm) were the 10 Vulcan railcars of 1940 for New Zealand.
Transmission types[edit]
Unlike steam engines, internal combustion engines require a transmission to power the wheels. The engine must be allowed to continue to run when the locomotive is stopped.
Diesel–mechanical[edit]
A diesel–mechanical locomotive uses a mechanical transmission in a fashion similar to that employed in most road vehicles. This type of transmission is generally limited to low-powered, low speed shunting (switching) locomotives, lightweight multiple units and self-propelled railcars.
The mechanical transmissions used for railroad propulsion are generally more complex and much more robust than standard-road versions. There is usually a fluid coupling interposed between the engine and gearbox, and the gearbox is often of the epicyclic (planetary) type to permit shifting while under load. Various systems have been devised to minimise the break in transmission during gear changing; e.g., the S.S.S. (synchro-self-shifting) gearbox used by Hudswell Clarke.
Diesel–mechanical propulsion is limited by the difficulty of building a reasonably sized transmission capable of coping with the power and torque required to move a heavy train. A number of attempts to use diesel–mechanical propulsion in high power applications have been made (e.g., the 1,500 kW (2,000 hp) British Rail 10100 locomotive), although none have proved successful in the end.
Diesel–electric[edit]
In a diesel–electric locomotive, the diesel engine drives either an electrical DC generator (generally, less than 3,000 horsepower (2,200 kW) net for traction), or an electrical AC alternator-rectifier (generally 3,000 horsepower (2,200 kW) net or more for traction), the output of which provides power to the traction motors that drive the locomotive. There is no mechanical connection between the diesel engine and the wheels.
The important components of diesel–electric propulsion are the diesel engine (also known as the prime mover), the main generator/alternator-rectifier, traction motors (usually with four or six axles), and a control system consisting of the engine governor and electrical or electronic components, including switchgear, rectifiers and other components, which control or modify the electrical supply to the traction motors. In the most elementary case, the generator may be directly connected to the motors with only very simple switchgear.
Originally, the traction motors and generator were DC machines. Following the development of high-capacity silicon rectifiers in the 1960s, the DC generator was replaced by an alternator using a diode bridge to convert its output to DC. This advance greatly improved locomotive reliability and decreased generator maintenance costs by elimination of the commutator and brushes in the generator. Elimination of the brushes and commutator, in turn, disposed of the possibility of a particularly destructive type of event referred to as a flashover, which could result in immediate generator failure and, in some cases, start an engine room fire.
Current North American practice is for four axles for high-speed passenger or 'time' freight, or for six axles for lower-speed or 'manifest' freight. The most modern units on 'time' freight service tend to have six axles underneath the frame. Unlike those in 'manifest' service, 'time' freight units will have only four of the axles connected to traction motors, with the other two as idler axles for weight distribution.
In the late 1980s, the development of high-power variable-voltage/variable-frequency (VVVF) drives, or 'traction inverters,' has allowed the use of polyphase AC traction motors, thus also eliminating the motor commutator and brushes. The result is a more efficient and reliable drive that requires relatively little maintenance and is better able to cope with overload conditions that often destroyed the older types of motors.
Diesel–electric control[edit]
A diesel–electric locomotive's power output is independent of road speed, as long as the unit's generator current and voltage limits are not exceeded. Therefore, the unit's ability to develop tractive effort (also referred to as drawbar pull or tractive force, which is what actually propels the train) will tend to inversely vary with speed within these limits. (See power curve below). Maintaining acceptable operating parameters was one of the principal design considerations that had to be solved in early diesel–electric locomotive development and, ultimately, led to the complex control systems in place on modern units.
Throttle operation[edit]
The prime mover's power output is primarily determined by its rotational speed (RPM) and fuel rate, which are regulated by a governor or similar mechanism. The governor is designed to react to both the throttle setting, as determined by the engine driver and the speed at which the prime mover is running.[37]
Locomotive power output, and thus speed, is typically controlled by the engine driver using a stepped or 'notched' throttle that produces binary-like electrical signals corresponding to throttle position. This basic design lends itself well to multiple unit (MU) operation by producing discrete conditions that assure that all units in a consist respond in the same way to throttle position. Binary encoding also helps to minimize the number of trainlines (electrical connections) that are required to pass signals from unit to unit. For example, only four trainlines are required to encode all possible throttle positions.
North American locomotives, such as those built by EMD or General Electric, have nine throttle positions, one idle and eight power (as well as an emergency stop position that shuts down the prime mover). Many UK-built locomotives have a ten-position throttle. The power positions are often referred to by locomotive crews as 'run 3' or 'notch 3', depending upon the throttle setting.
In older locomotives, the throttle mechanism was ratcheted so that it was not possible to advance more than one power position at a time. The engine driver could not, for example, pull the throttle from notch 2 to notch 4 without stopping at notch 3. This feature was intended to prevent rough train handling due to abrupt power increases caused by rapid throttle motion ('throttle stripping,' an operating rules violation on many railroads). Modern locomotives no longer have this restriction, as their control systems are able to smoothly modulate power and avoid sudden changes in train loading regardless of how the engine driver operates the controls.
When the throttle is in the idle position, the prime mover will be receiving minimal fuel, causing it to idle at low RPM. In addition, the traction motors will not be connected to the main generator and the generator's field windings will not be excited (energized) — the generator will not produce electricity with no excitation. Therefore, the locomotive will be in 'neutral'. Conceptually, this is the same as placing an automobile's transmission into neutral while the engine is running.
To set the locomotive in motion, the reverser control handle is placed into the correct position (forward or reverse), the brake is released and the throttle is moved to the run 1 position (the first power notch). An experienced engine driver can accomplish these steps in a coordinated fashion that will result in a nearly imperceptible start. The positioning of the reverser and movement of the throttle together is conceptually like shifting an automobile's automatic transmission into gear while the engine is idling
Placing the throttle into the first power position will cause the traction motors to be connected to the main generator and the latter's field coils to be excited. With excitation applied, the main generator will deliver electricity to the traction motors, resulting in motion. If the locomotive is running 'light' (that is, not coupled to the rest of a train) and is not on an ascending grade, it will easily accelerate. On the other hand, if a long train is being started, the locomotive may stall as soon as some of the slack has been taken up, as the drag imposed by the train will exceed the tractive force being developed. An experienced engine driver will be able to recognize an incipient stall and will gradually advance the throttle as required to maintain the pace of acceleration.
As the throttle is moved to higher power notches, the fuel rate to the prime mover will increase, resulting in a corresponding increase in RPM and horsepower output. At the same time, main generator field excitation will be proportionally increased to absorb the higher power. This will translate into increased electrical output to the traction motors, with a corresponding increase in tractive force. Eventually, depending on the requirements of the train's schedule, the engine driver will have moved the throttle to the position of maximum power and will maintain it there until the train has accelerated to the desired speed.
The propulsion system is designed to produce maximum traction motor torque at start-up, which explains why modern locomotives are capable of starting trains weighing in excess of 15,000 tons, even on ascending grades. Current technology allows a locomotive to develop as much as 30% of its loaded driver weight in tractive force, amounting to 120,000 pounds-force (530 kN) of tractive force for a large, six-axle freight (goods) unit. In fact, a consist of such units can produce more than enough drawbar pull at start-up to damage or derail cars (if on a curve) or break couplers (the latter being referred to in North American railroad slang as 'jerking a lung'). Therefore, it is incumbent upon the engine driver to carefully monitor the amount of power being applied at start-up to avoid damage. In particular, 'jerking a lung' could be a calamitous matter if it were to occur on an ascending grade, except that the safety inherent in the correct operation of automatic train brakes installed in wagons today, prevents runaway trains by automatically applying the wagon brakes when train line air pressure drops.
Propulsion system operation[edit]
A locomotive's control system is designed so that the main generator electrical power output is matched to any given engine speed. Given the innate characteristics of traction motors, as well as the way in which the motors are connected to the main generator, the generator will produce high current and low voltage at low locomotive speeds, gradually changing to low current and high voltage as the locomotive accelerates. Therefore, the net power produced by the locomotive will remain constant for any given throttle setting (see power curve graph for notch 8).
In older designs, the prime mover's governor and a companion device, the load regulator, play a central role in the control system. The governor has two external inputs: requested engine speed, determined by the engine driver's throttle setting, and actual engine speed (feedback). The governor has two external control outputs: fuel injector setting, which determines the engine fuel rate, and load regulator position, which affects main generator excitation. The governor also incorporates a separate overspeed protective mechanism that will immediately cut off the fuel supply to the injectors and sound an alarm in the cab in the event the prime mover exceeds a defined RPM. Not all of these inputs and outputs are necessarily electrical.
The load regulator is essentially a large potentiometer that controls the main generator power output by varying its field excitation and hence the degree of loading applied to the engine. Kodi app not installed firestick. The load regulator's job is relatively complex, because although the prime mover's power output is proportional to RPM and fuel rate, the main generator's output is not (which characteristic was not correctly handled by the Ward Leonard elevator- and hoist-type drive system that was initially tried in early locomotives). Instead, a quite complex electro-hydraulic Woodward governor was employed. Today, this important function would be performed by the Engine control unit, itself being a part of the Locomotive control unit.
As the load on the engine changes, its rotational speed will also change. This is detected by the governor through a change in the engine speed feedback signal. The net effect is to adjust both the fuel rate and the load regulator position so that engine RPM and torque (and thus power output) will remain constant for any given throttle setting, regardless of actual road speed.
In newer designs controlled by a “traction computer,” each engine speed step is allotted an appropriate power output, or “kW reference”, in software. The computer compares this value with actual main generator power output, or “kW feedback”, calculated from traction motor current and main generator voltage feedback values. The computer adjusts the feedback value to match the reference value by controlling the excitation of the main generator, as described above. The governor still has control of engine speed, but the load regulator no longer plays a central role in this type of control system. However, the load regulator is retained as a “back-up” in case of engine overload. Modern locomotives fitted with electronic fuel injection (EFI) may have no mechanical governor; however, a “virtual” load regulator and governor are retained with computer modules.
Traction motor performance is controlled either by varying the DC voltage output of the main generator, for DC motors, or by varying the frequency and voltage output of the VVVF for AC motors. With DC motors, various connection combinations are utilized to adapt the drive to varying operating conditions.
At standstill, main generator output is initially low voltage/high current, often in excess of 1000 amperes per motor at full power. When the locomotive is at or near standstill, current flow will be limited only by the DC resistance of the motor windings and interconnecting circuitry, as well as the capacity of the main generator itself. Torque in a series-wound motor is approximately proportional to the square of the current. Hence, the traction motors will produce their highest torque, causing the locomotive to develop maximum tractive effort, enabling it to overcome the inertia of the train. This effect is analogous to what happens in an automobile automatic transmission at start-up, where it is in first gear and thus producing maximum torque multiplication.
As the locomotive accelerates, the now-rotating motor armatures will start to generate a counter-electromotive force (back EMF, meaning the motors are also trying to act as generators), which will oppose the output of the main generator and cause traction motor current to decrease. Main generator voltage will correspondingly increase in an attempt to maintain motor power, but will eventually reach a plateau. At this point, the locomotive will essentially cease to accelerate, unless on a downgrade. Since this plateau will usually be reached at a speed substantially less than the maximum that may be desired, something must be done to change the drive characteristics to allow continued acceleration. This change is referred to as 'transition,' a process that is analogous to shifting gears in an automobile.
Transition methods include:
- Series / Parallel or 'motor transition'.
- Initially, pairs of motors are connected in series across the main generator. At higher speed, motors are reconnected in parallel across the main generator.
- 'Field shunting', 'field diverting', or 'weak fielding'.
- Resistance is connected in parallel with the motor field. This has the effect of increasing the armature current, producing a corresponding increase in motor torque and speed.
Both methods may also be combined, to increase the operating speed range.
- Generator / rectifier transition
- Reconnecting the two separate internal main generator stator windings of two rectifiers from parallel to series to increase the output voltage.
In older locomotives, it was necessary for the engine driver to manually execute transition by use of a separate control. As an aid to performing transition at the right time, the load meter (an indicator that shows the engine driver how much current is being drawn by the traction motors) was calibrated to indicate at which points forward or backward transition should take place. Automatic transition was subsequently developed to produce better-operating efficiency and to protect the main generator and traction motors from overloading from improper transition.
Modern locomotives incorporate traction inverters, AC to DC, with the capability to deliver 1,200 volts (earlier traction generators, DC to DC, had the capability to deliver only 600 volts). This improvement was accomplished largely through improvements in silicon diode technology. With the capability to deliver 1,200 volts to the traction motors, the necessity for 'transition' was eliminated.
Dynamic braking[edit]
A common option on diesel–electric locomotives is dynamic (rheostatic) braking.
Dynamic braking takes advantage of the fact that the traction motor armatures are always rotating when the locomotive is in motion and that a motor can be made to act as a generator by separately exciting the field winding. When dynamic braking is utilized, the traction control circuits are configured as follows:
- The field winding of each traction motor is connected across the main generator.
- The armature of each traction motor is connected across a forced-air-cooled resistance grid (the dynamic braking grid) in the roof of the locomotive's hood.
- The prime mover RPM is increased and the main generator field is excited, causing a corresponding excitation of the traction motor fields.
The aggregate effect of the above is to cause each traction motor to generate electric power and dissipate it as heat in the dynamic braking grid. A fan connected across the grid provides forced-air cooling. Consequently, the fan is powered by the output of the traction motors and will tend to run faster and produce more airflow as more energy is applied to the grid.
Ultimately, the source of the energy dissipated in the dynamic braking grid is the motion of the locomotive as imparted to the traction motor armatures. Therefore, the traction motors impose drag and the locomotive acts as a brake. As speed decreases, the braking effect decays and usually becomes ineffective below approximately 16 km/h (10 mph), depending on the gear ratio between the traction motors and axles.
Dynamic braking is particularly beneficial when operating in mountainous regions; where there is always the danger of a runaway due to overheated friction brakes during descent. In such cases, dynamic brakes are usually applied in conjunction with the air brakes, the combined effect being referred to as blended braking. The use of blended braking can also assist in keeping the slack in a long train stretched as it crests a grade, helping to prevent a 'run-in', an abrupt bunching of train slack that can cause a derailment. Blended braking is also commonly used with commuter trains to reduce wear and tear on the mechanical brakes that is a natural result of the numerous stops such trains typically make during a run.
Electro-diesel[edit]
These special locomotives can operate as an electric locomotive or as a diesel locomotive. The Long Island Rail Road, Metro-North Railroad and New Jersey Transit Rail Operations operate dual-mode diesel–electric/third-rail (catenary on NJTransit) locomotives between non-electrified territory and New York City because of a local law banning diesel-powered locomotives in Manhattan tunnels. For the same reason, Amtrak operates a fleet of dual-mode locomotives in the New York area. British Rail operated dual diesel–electric/electric locomotives designed to run primarily as electric locomotives with reduced power available when running on diesel power. This allowed railway yards to remain un-electrified, as the third rail power system is extremely hazardous in a yard area.
Diesel–hydraulic[edit]
Diesel–hydraulic locomotives use one or more torque converters, in combination with gears, with a mechanical final drive to convey the power from the diesel engine to the wheels.
Hydrostatic transmission[edit]
Hydraulic drive systems using a hydrostatic hydraulic drive system have been applied to rail use. Modern examples included 350 to 750 hp (260 to 560 kW) shunting locomotives by Cockerill (Belgium),[38] 4 to 12 tonne 35 to 58 kW (47 to 78 hp) narrow gauge industrial locomotives by Atlas Copco subsidiary GIA.[39] Hydrostatic drives are also utilised in railway maintenance machines (tampers, rail grinders).[40]
Application of hydrostatic transmissions is generally limited to small shunting locomotives and rail maintenance equipment, as well as being used for non-tractive applications in diesel engines such as drives for traction motor fans.[citation needed]
Hydrokinetic transmission[edit]
Hydrokinetic transmission (also called hydrodynamic transmission) uses a torque converter. A torque converter consists of three main parts, two of which rotate, and one (the stator) that has a lock preventing backwards rotation and adding output torque by redirecting the oil flow at low output RPM. All three main parts are sealed in an oil-filled housing. To match engine speed to load speed over the entire speed range of a locomotive some additional method is required to give sufficient range. One method is to follow the torque converter with a mechanical gearbox which switches ratios automatically, similar to an automatic transmission in an automobile. Another method is to provide several torque converters each with a range of variability covering part of the total required; all the torque converters are mechanically connected all the time, and the appropriate one for the speed range required is selected by filling it with oil and draining the others. The filling and draining is carried out with the transmission under load, and results in very smooth range changes with no break in the transmitted power.
Locomotives[edit]
Diesel–hydraulic locomotives are less efficient than diesel–electrics. The first-generation BR diesel hydraulics were significantly less efficient (c. 65%) than diesel electrics (c. 80%)[citation needed] — moreover initial versions were found in many countries to be mechanically more complicated and more likely to break down.[citation needed] Hydraulic transmission for locomotives was developed in Germany.[citation needed] There is still debate over the relative merits of hydraulic vs. electrical transmission systems: advantages claimed for hydraulic systems include lower weight, high reliability, and lower capital cost.[citation needed]
By the 21st century, for diesel locomotive traction worldwide the majority of countries used diesel–electric designs, with diesel-hydraulic designs not found in use outside Germany and Japan, and some neighbouring states, where it is used in designs for freight work.
In Germany and Finland, diesel–hydraulic systems have achieved high reliability in operation.[citation needed] In the UK the diesel–hydraulic principle gained a poor reputation due to the poor durability and reliability of the Maybach Mekydro hydraulic transmission.[citation needed] Argument continues over the relative reliability of hydraulic systems, with questions over whether data has been manipulated to favour local suppliers over non-German ones.[citation needed]
Multiple units[edit]
Diesel–hydraulic drive is common in multiple units, with various transmission designs used including Voith torque converters, and fluid couplings in combination with mechanical gearing.
The majority of British Rail's second generation passenger DMU stock used hydraulic transmission. In the 21st century, designs using hydraulic transmission include Bombardier'sTurbostar, Talent, RegioSwinger families; diesel engined versions of Siemens'sDesiro platform, and the Stadler Regio-Shuttle.
Examples[edit]
Diesel–hydraulic locomotives have a smaller market share than those with diesel-electric transmission - the main worldwide user of main-line hydraulic transmissions was the Federal Republic of Germany, with designs including the 1950s DB class V 200, and the 1960 and 1970s DB Class V 160 family. British Rail introduced a number of diesel-hydraulic designs during it 1955 Modernisation Plan, initially license-built versions of German designs (see Category:Diesel–hydraulic locomotives of Great Britain). In Spain, RENFE used high power to weight ratio twin-engined German designs to haul high speed trains from the 1960s to 1990s. (see RENFE Classes 340, 350, 352, 353, 354)
Other main-line locomotives of the post war period included the 1950s GMD GMDH-1 experimental locomotives; the Henschel & Son built South African Class 61-000; in the 1960s Southern Pacific bought 18 Krauss-Maffei KM ML-4000 diesel–hydraulic locomotives. The Denver & Rio Grande Western also bought three, all of which were later sold to SP.[41]
In Finland, over 200 Finnish-built VR class Dv12 and Dr14 diesel–hydraulics with Voith transmissions have been continuously used since the early 1960s. All units of Dr14 class and most units of Dv12 class are still in service. VR has abandoned some weak-conditioned units of 2700 series Dv12s.[42]
In the 21st century series production standard gauge diesel–hydraulic designs include the Voith Gravita, ordered by Deutsche Bahn, and the Vossloh G2000, G1206 and G1700 designs, all manufactured in Germany for freight use.
Diesel–steam[edit]
Steam-diesel hybrid locomotives can use steam generated from a boiler or diesel to power a piston engine. The Cristiani Compressed Steam System used a diesel engine to power a compressor to drive and recirculate steam produced by a boiler; effectively using steam as the power transmission medium, with the diesel engine being the prime mover[43]
Diesel–pneumatic[edit]
The diesel-pneumatic locomotive was of interest in the 1930s because it offered the possibility of converting existing steam locomotives to diesel operation. The frame and cylinders of the steam locomotive would be retained and the boiler would be replaced by a diesel engine driving an air compressor. The problem was low thermal efficiency because of the large amount of energy wasted as heat in the air compressor. Attempts were made to compensate for this by using the diesel exhaust to re-heat the compressed air but these had limited success. A German proposal of 1929 did result in a prototype[44] but a similar British proposal of 1932, to use an LNER Class R1 locomotive, never got beyond the design stage.
Multiple-unit operation[edit]
Most diesel locomotives are capable of multiple-unit train control (MU) as a means of increasing horsepower and tractive effort when hauling heavy trains. All North American locomotives, including export models, use a standardized AAR electrical control system interconnected by a 27-pin jumper cable between the units. For UK-built locomotives, a number of incompatible control systems are used, but the most common is the Blue Star system, which is electro-pneumatic and fitted to most early diesel classes. A small number of types, typically higher-powered locomotives intended for passenger only work, do not have multiple control systems. In all cases, the electrical control connections made common to all units in a consist are referred to as trainlines. The result is that all locomotives in a consist behave as one in response to the engine driver's control movements.
The ability to couple diesel–electric locomotives in an MU fashion was first introduced in the EMD FT four-unit demonstrator that toured the United States in 1939. At the time, American railroad work rules required that each operating locomotive in a train had to have on board a full crew. EMD circumvented that requirement by coupling the individual units of the demonstrator with drawbars instead of conventional knuckle couplers and declaring the combination to be a single locomotive. Electrical interconnections were made so one engine driver could operate the entire consist from the head-end unit. Later on, work rules were amended and the semi-permanent coupling of units with drawbars was eliminated in favour of couplers, as servicing had proved to be somewhat cumbersome owing to the total length of the consist (about 200 feet or nearly 61 meters).
In mountainous regions, it is common to interpose helper locomotives in the middle of the train, both to provide the extra power needed to ascend a grade and to limit the amount of stress applied to the draft gear of the car coupled to the head-end power. The helper units in such distributed power configurations are controlled from the lead unit's cab through coded radio signals. Although this is technically not an MU configuration, the behaviour is the same as with physically interconnected units.
Cab arrangements[edit]
Cab arrangements vary by builder and operator. Practice in the U.S. has traditionally been for a cab at one end of the locomotive with limited visibility if the locomotive is not operated cab forward. This is not usually a problem as U.S. locomotives are usually operated in pairs, or threes, and arranged so that a cab is at each end of each set. European practice is usually for a cab at each end of the locomotive as trains are usually light enough to operate with one locomotive. Early U.S. practice was to add power units without cabs (booster or B units) and the arrangement was often A-B, A-A, A-B-A, A-B-B, or A-B-B-A where A was a unit with a cab. Center cabs were sometimes used for switch locomotives.
Cow-calf[edit]
In North American railroading, a cow-calf set is a pair of switcher-type locomotives: one (the cow) equipped with a driving cab, the other (the calf) without a cab, and controlled from the cow through cables. Cow-calf sets are used in heavy switching and hump yard service. Some are radio controlled without an operating engineer present in the cab. This arrangement is also known as master-slave. Where two connected units were present, EMD called these TR-2s (approximately 2,000 hp or 1,500 kW); where three units, TR-3s (approximately 3,000 hp or 2,200 kW).
Cow-calves have largely disappeared as these engine combinations exceeded their economic lifetimes many years ago.
Fairbanks Ward Generator Manual
Present North American practice is to pair two 3,000 hp (2,200 kW) GP40-2 or SD40-2 road switchers, often nearly worn-out and very soon ready for rebuilding or scrapping, and to utilize these for so-called 'transfer' uses, for which the TR-2, TR-3 and TR-4 engines were originally intended, hence the designation TR, for 'transfer'.
Occasionally, the second unit may have its prime-mover and traction alternator removed and replaced by concrete or steel ballast and the power for traction obtained from the master unit. As a 16-cylinder prime-mover generally weighs in the 36,000-pound (16,000 kg) range, and a 3,000 hp (2,200 kW) traction alternator generally weighs in the 18,000-pound (8,200 kg) range, this would mean that 54,000 lb (24,000 kg) would be needed for ballast.
A pair of fully capable 'Dash 2' units would be rated 6,000 hp (4,500 kW). A 'Dash 2' pair where only one had a prime-mover/alternator would be rated 3,000 hp (2,200 kW), with all power provided by master, but the combination benefits from the tractive effort provided by the slave as engines in transfer service are seldom called upon to provide 3,000 hp (2,200 kW) much less 6,000 hp (4,500 kW) on a continuous basis.
Fittings and appliances[edit]
Flameproofing[edit]
A standard diesel locomotive presents a very low fire risk but “flame proofing” can reduce the risk even further. This involves fitting a water-filled box to the exhaust pipe to quench any red-hot carbon particles that may be emitted. Other precautions may include a fully insulated electrical system (neither side earthed to the frame) and all electric wiring enclosed in conduit.
The flameproof diesel locomotive has replaced the fireless steam locomotive in areas of high fire risk such as oil refineries and ammunition dumps. Preserved examples of flameproof diesel locomotives include:
- Francis Baily of Thatcham (ex-RAF Welford) at Southall Railway Centre
- Naworth (ex-National Coal Board) at the South Tynedale Railway[45]
Latest development of the 'Flameproof Diesel Vehicle Applied New Exhaust Gas Dry Type Treatment System” does not need the water supply.[46]
Lights[edit]
The lights fitted to diesel locomotives vary from country to country. North American locomotives are fitted with two headlights (for safety in case one malfunctions) and a pair of ditch lights. The latter are fitted low down at the front and are designed to make the locomotive easily visible as it approaches a grade crossing. Older locomotives may be fitted with a Gyralite or Mars Light instead of the ditch lights.
Environmental impact[edit]
Although diesel locomotives generally emit less sulphur dioxide, a major pollutant to the environment, and greenhouse gases than steam locomotives, they are not completely clean in that respect.[47] Furthermore, like other diesel powered vehicles, they emit nitrogen oxides and fine particles, which are a risk to public health. In fact, in this last respect diesel locomotives may perform worse than steam locomotives.
For years, it was thought by American government scientists who measure air pollution that diesel locomotive engines were relatively clean and emitted far less health-threatening emissions than those of diesel trucks or other vehicles; however, the scientists discovered that because they used faulty estimates of the amount of fuel consumed by diesel locomotives, they grossly understated the amount of pollution generated annually (In Europe, where most major railways have been electrified, there is less concern). After revising their calculations, they concluded that the annual emissions of nitrogen oxide, a major ingredient in smog and acid rain, and soot would be by 2030 nearly twice what they originally assumed.[48][49]
This would mean that diesel locomotives would be releasing more than 800,000 tons of nitrogen oxide and 25,000 tons of soot every year within a quarter of a century, in contrast to the EPA's previous projections of 480,000 tons of nitrogen dioxide and 12,000 tons of soot. Since this was discovered, to reduce the effects of the diesel locomotive on humans (who are breathing the noxious emissions) and on plants and animals, it is considered practical to install traps in the diesel engines to reduce pollution levels[50] and other forms (e.g., use of biodiesel).
Diesel locomotive pollution has been of particular concern in the city of Chicago. The Chicago Tribune reported levels of diesel soot inside locomotives leaving Chicago at levels hundreds of times above what is normally found on streets outside.[51] Residents of several neighborhoods are most likely exposed to diesel emissions at levels several times higher than the national average for urban areas.[52]
Mitigation[edit]
In 2008, the United States Environmental Protection Agency (EPA) mandated regulations requiring all new or refurbished diesel locomotives to meet Tier II pollution standards that slash the amount of allowable soot by 90% and require an 80% reduction in nitrogen oxide emissions. SeeList of low emissions locomotives.
Other technologies that are being deployed to reduce locomotive emissions and fuel consumption include 'Genset' switching locomotives and hybrid Green Goat designs. Genset locomotives use multiple smaller high-speed diesel engines and generators (generator sets), rather than a single medium-speed diesel engine and a single generator.[53] Because of the cost of developing clean engines, these smaller high-speed engines are based on already developed truck engines. Green Goats are a type of hybrid switching locomotive utilizing a small diesel engine and a large bank of rechargeable batteries.[54][55] Switching locomotives are of particular concern as they typically operate in a limited area, often in or near urban centers, and spend much of their time idling. Both designs reduce pollution below EPA Tier II standards and cut or eliminate emissions during idle.
Diesel's advantages over steam[edit]
As diesel locomotives advanced, the cost of manufacturing and operating them dropped, and they became cheaper to own and operate than steam locomotives. In North America, steam locomotives were custom-made for specific railway routes, so economies of scale were difficult to achieve.[56] Though more complex to produce with exacting manufacturing tolerances (1⁄10000-inch or 0.0025-millimetre for diesel, compared with 1⁄100-inch (0.25 mm) for steam), diesel locomotive parts were easier to mass produce. Baldwin Locomotive Works offered almost five hundred steam models in its heyday, while EMD offered fewer than ten diesel varieties.[57] In the United Kingdom, British Railways built steam locomotives to standard designs from 1951 onwards. These included standard, interchangeable parts, and were cheaper to produce than the diesel locomotives then available. The capital cost per drawbar horse power was £13 6s (steam), £65 (diesel), £69 7s (turbine) and £17 13s (electric).[58]
Diesel locomotives offer significant operating advantages over steam locomotives.[59] They can safely be operated by one person, making them ideal for switching/shunting duties in yards (although for safety reasons many main-line diesel locomotives continue to have 2-man crews: an engineer and a conductor/switchman) and the operating environment is much more attractive, being quieter, fully weatherproof and without the dirt and heat that is an inevitable part of operating a steam locomotive. Diesel locomotives can be worked in multiple with a single crew controlling multiple locomotives in a single train — something not practical with steam locomotives. This brought greater efficiencies to the operator, as individual locomotives could be relatively low-powered for use as a single unit on light duties but marshaled together to provide the power needed on a heavy train. With steam traction, a single very powerful and expensive locomotive was required for the heaviest trains or the operator resorted to double heading with multiple locomotives and crews, a method which was also expensive and brought with it its own operating difficulties.
Diesel engines can be started and stopped almost instantly, meaning that a diesel locomotive has the potential to incur no fuel costs when not being used. However, it is still the practice of large North American railroads to use straight water as a coolant in diesel engines instead of coolants that incorporate anti-freezing properties; this results in diesel locomotives being left idling when parked in cold climates instead of being completely shut down. A diesel engine can be left idling unattended for hours or even days, especially since practically every diesel engine used in locomotives has systems that automatically shut the engine down if problems such as a loss of oil pressure or coolant loss occur. Automatic start/stop systems are available which monitor coolant and engine temperatures. When the unit is close to having its coolant freeze, the system restarts the diesel engine to warm the coolant and other systems.[60]
Steam locomotives require intensive maintenance, lubrication, and cleaning before, during, and after use. Preparing and firing a steam locomotive for use from cold can take many hours. They can be kept in readiness between uses with a low fire, but this requires regular stoking and frequent attention to maintain the level of water in the boiler. This may be necessary to prevent the water in the boiler freezing in cold climates, so long as the water supply itself is not frozen.
The maintenance and operational costs of steam locomotives were much higher than diesels. Annual maintenance costs for steam locomotives accounted for 25% of the initial purchase price. Spare parts were cast from wooden masters for specific locomotives. The sheer number of unique steam locomotives meant that there was no feasible way for spare-part inventories to be maintained.[61] With diesel locomotives spare parts could be mass-produced and held in stock ready for use and many parts and sub-assemblies could be standardized across an operator's fleet using different models of locomotive from the same builder. Modern diesel locomotive engines are designed to allow the power assemblies (systems of working parts and their block interfaces) to be replaced while keeping the main block in the locomotive, which greatly reduces the time that a locomotive is out of revenue-generating service when it requires maintenance.[26]
Steam engines required large quantities of coal and water, which were expensive variable operating costs.[62] Further, the thermal efficiency of steam was considerably less than that of diesel engines. Diesel's theoretical studies demonstrated potential thermal efficiencies for a compression ignition engine of 36% (compared with 6–10% for steam), and an 1897 one-cylinder prototype operated at a remarkable 26% efficiency.[63]
However, one study published in 1959 suggested that many of the comparisons between diesel and steam locomotives were made unfairly mostly because diesels were newer. After painstaking analysis of financial records and technological progress, the author found that if research had continued on steam technology instead of diesel, there would be negligible financial benefit in converting to diesel locomotion.[64]
By the mid-1960s, diesel locomotives had effectively replaced steam locomotives where electric traction was not in use.[62] Attempts to develop advanced steam technology continue in the 21st century but have not made a significant impact.
See also[edit]
References[edit]
Fairbanks Ward Generator Manual
- ^U.S. 608,845, Rudolf Diesel, 'Internal-combustion engine', issued 9 August 1898
- ^Arnold Heller: Der Automobilmotor im Eisenbahnbetriebe, Leipzig 1906, reprinted by Salzwasserverlag 2011, ISBN978-3-86444-240-7
- ^Röll: Enzyklopädie des Eisenbahnwesens → Elektrische Eisenbahnen, there go to VII. Automobile Triebwagen → zu b Benzin-, Benzol- oder Gasolin-elektrischen Triebwagen
- ^Raymond S Zeitler, American School (Chicago, Ill.): Self-Contained Railway Motor Cars and Locomotives, section SELF-CONTAINED RAILWAY CARS 57–59
- ^Röll: Arader und Csanáder Eisenbahnen Vereinigte Aktien-Gesellschaft
- ^Museal railcars of BHÉV and their history
- ^'Motive power for British Railways'(PDF), The Engineer, vol. 202, p. 254, 24 April 1956, archived from the original(PDF) on 4 March 2014, retrieved 28 February 2014
- ^The Electrical Review, 22: 474, 4 May 1888,
A small double cylinder engine has been mounted upon a truck, which is worked on a temporary line of rails, in order to show the adaptation of a petroleum engine for locomotive purposes, on tramways
Missing or emptytitle=
(help) - ^Diesel Railway Traction, 17: 25, 1963,
In one sense a dock authority was the earliest user of an oil-engined locomotive, for it was at the Hull docks of the North Eastern Railway that the Priestman locomotive put in its short period of service in 1894
Missing or emptytitle=
(help) - ^Day, John R.; Cooper, Basil Knowlman (1960), railway Locomotives, Frederick Muller, p. 42,
The diesel has quite a long history, and the first one ran as far back as 1894. This was a tiny 30-h.p. two-axle standard-gauge locomotive with a two- cylinder engine designed by William Dent Priestman
- ^Webb, Brian (1973). The British Internal Combustion Locomotive 1894-1940. David & Charles. ISBN978-0715361153.
- ^Churella 1998, p. 15.
- ^Churella 1998, p. 12.
- ^Glatte, Wolfgang (1993). Deutsches Lok-Archiv: Diesellokomotiven 4. Auflage. Berlin: Transpress. ISBN978-3-344-70767-5.
- ^ abStover, John F. (1997). American Railroads. Chicago, Illinois: The University of Chicago Press. p. 212. ISBN978-0-226-77658-3.
- ^Edison, Thomas A. U.S. Patent No. 493,425, filed January 19, 1891, and issued March 14, 1891 Accessed via the Edison Papers at: US Patent #493,425 on February 8, 2007.
- ^Lemp, Hermann. U.S. Patent No. 1,154,785, filed April 8, 1914, and issued September 28, 1915. Accessed via Google Patent Search at: US Patent #1,154,785 on February 8, 2007.
- ^Pinkepank 1973, pp. 139–141
- ^Churella 1998, pp. 25-27.
- ^Evolution of the American Diesel Locomotive, J Parker Lamb 2007, Indiana University Press, ISBN978-0-253-34863-0, p.29
- ^Churella 1998, pp. 28-30.
- ^'Railroads To Try Diesel Locomotive', Special to the New York Times, p. 1, February 18, 1925
- ^Pinkepank 1973, p. 283.
- ^Churella 1998, p. 27.
- ^Pinkepank 1973, p. 409.
- ^ abKettering, E.W. (29 November 1951). History and Development of the 567 Series General Motors Locomotive Engine(PDF). ASME 1951 Annual Meeting. Atlantic City, New Jersey: Electro-Motive Division, General Motors Corporation. Retrieved 6 January 2015.
- ^'Diesel Streamliners Now Link Coast-to-Coast'Popular Mechanics, August 1937
- ^Pinkepank 1973, p. 209–211.
- ^Solomon, Brian, Locomotive, 2001, pp 120, 130
- ^'vecchia loco ferrovie della Calabria - Ferrovie.it'. www.ferrovie.it.
- ^'The first russian diesel locos'. izmerov.narod.ru.
- ^'DD50 5 DD50 2|随時アップ:消えた車輌写真館|鉄道ホビダス'. rail.hobidas.com.
- ^'キハ43000の資料 - しるねこの微妙な生活/浮気心あれば水心!?'.
- ^Burke, A 1991., Rails through the Wilderness; New South Wales University Press
- ^Holden, R 2006 No. 259 : the curious story of a forgotten locomotive, Railmac Publications
- ^Rail Motors and XPTs, David Cooke, ARHS, NSW Division, 1984 pp40-59
- ^Control theory
- ^'Shunting locomotives'. www.cmigroupe.com. Retrieved 29 June 2019.
- ^'Locomotives', www.gia.se, archived from the original on 2014-03-30, retrieved 1 February 2014
- ^Solomon, Brian (2001), Railway Maintenance Equipment: The Men and Machines That Keep the Railroads Running, Voyager Press, pp. 78, 96, ISBN978-0760309759
- ^Marre, Louis A. (1995). Diesel Locomotives: The First Fifty Years. Waukesha, Wis., USA: Kalmbach. pp. 384–385. ISBN978-0-89024-258-2.
- ^Suruliputus saatteli veturit viimeiselle matkalle(in Finnish)
- ^The Paragon-Cristiani Compressed Steam Systemdslef.dsl.pipex.com
- ^'A German Diesel-Pneumatic Locomotive'. Douglas-self.com. Retrieved 2011-08-20.
- ^[1]Archived January 6, 2009, at the Wayback Machine
- ^'Development of the Flameproof Diesel Vehicle Applied New Exhaust Gas Dry Type Treatment System'. Sciencelinks.jp. 2009-03-18. Archived from the original on 2012-02-17. Retrieved 2011-08-20.
- ^King, Joe (2008-09-22). 'Engineering gets $1 million grant to make locomotives leaner, greener'. Northern Illinois University. Archived from the original on 2012-09-10. Retrieved 2011-08-06.
- ^Eilperin, Juliet (2006-08-14). 'Attention to Locomotives' Emissions Renewed'. Washington Post. Retrieved 2011-08-06.
- ^Hawthorne, Michael (February 14, 2011). 'Metra finds 'alarming' pollution on some trains'. Chicago Tribune. Retrieved 2011-08-06.
- ^Wilkins, Davell (2011-04-13). 'Study: Installed Traps In Diesel Engines Reduce Pollution Levels'. Top News. Retrieved 2011-08-06.
- ^'Pollution on Metra Trains Worse Than Thought: Report'. Fox Chicago News. 2011-02-14. Retrieved 2011-08-06.
- ^Lydersen, Kari (April 21, 2011). 'Black Carbon Testing Finds High Levels'. The New York Times. Retrieved August 6, 2011.
- ^'Multi-Engine GenSet Ultra Low Emissions Road-Switcher Locomotive'(PDF). National Railway Equipment Company. Retrieved 2012-06-03.
- ^'Railpower Technologies Products'. Archived from the original on January 14, 2008. Retrieved 2012-06-03.
- ^RJ Corman Railpower Genset & Hybrid Switchers. Trainweb.org. Retrieved on 2013-08-16.
- ^Churella 1998, p. 10.
- ^Churella 1998, p. 19.
- ^'Standardisation and Comparative Costs of Motive Power on B.R.'. Railway Magazine: 60–61. January 1951.
- ^http://www.sdrm.org/faqs/hostling.html, Phil Jern 'How to Boot a Steam Locomotive' (1990) San Diego Railroad Museum.
- ^SmartStart® IIe - Automatic Engine Start/Stop System. Ztr.com. Retrieved on 2013-08-16.
- ^Churella 1998, pp. 12-17.
- ^ abStover, 213
- ^Churella 1998, p. 14.
- ^Brown, H. F. (1959). Economic results of diesel-electric motive power on the railways in the United States. Proceedings of the Institution of Mechanical Engineers, 175(1), 257-317. doi:10.1243/PIME_PROC_1961_175_025_02
Sources[edit]
- Churella, Albert J. (1998). From Steam to Diesel: Managerial Customs and Organizational Capabilities in the Twentieth-Century American Locomotive Industry. Princeton, New Jersey: Princeton University Press. ISBN978-0-691-02776-0.
- Pinkepank, Jerry A. (1973). The Second Diesel Spotter's Guide. Milwaukee WI: Kalmbach Books. ISBN978-0-89024-026-7.
External links[edit]
Wikimedia Commons has media related to Diesel locomotives. |